Alert Data – The following will output the state of the alarm at the time of the measurement. A value of 1
indicates that the alert was active, and 0 indicates that the alert was off.
Line Pressure High Line Pressure Low Sensor 1 Press High
Sensor 2 Press High Sensor 1 Press Low Sensor 2 Press low
Sensor 1 Temp High Sensor 1 Temp Low Sensor 2 Temp High
Sensor 2 Temp Low Extend Time Low Extend Time High
Retract Time Low Retract Time High Rear Seal Failure
Front Seal Failure Rod Seal Failure
To export the logged data:
1. Select the Pressure and Date Export option button
Figure 48: Export option
2. The eld selector will appear. On the right is a list of all of the available pieces of data. On the left is a grey
area where the desired elds can be dragged.
Figure 49: Export eld selector
3. By default, the export le will contain the measurement time and the two pressure measurements, P1
and P2. To add any of the available elds/columns to the exported le, press the left button over the re-
quired eld and drag it to the space to the left. The “Select All” command moves all of the column names
to the left column, adding them to the export report, and the “Clear” command clears any selected
column names.
Figure 50: Select variable to export
4. Items in the list can be rearranged to represent the column order in the exported le from left to right.