IntelliSense
®
Manual
9
Functionality
• Cylinder condition monitoring based on status LEDs on SIM unit
• By conguring a MODBUS RTU network between the users’ PLC/HMI (Master Device) and the SIM unit(s)
(Slave Device), the user can retrieve desired status values and alerts
• User PC connects to SIM for initial conguration and/or real time monitoring of the SIM unit and attached
pressure system
• Use of EOT outputs with PLC installation and use of power option b
List of Components
Required Bimba Products
• IntelliSense
®
Basic Kit- [ISK-BMAx]
o 1 - IntelliSense
®
Sensor Interface Module (SIM) [ISM-S1-BA1-5P]
o 2 - IntelliSense
®
pressure / temperature sensor [ISS-1A-7SS]
o 2 - IntelliSense
®
Tee ttings [ISF-T1-xxx]
• 2 - IntelliSense
®
sensor cable [CBL-IS-M8-x]
• 1 - IntelliSense
®
USB programming cable [CBL-IS-RU-1.8]
• 1 – IntelliSense
®
Data Gateway [ISG-01]
Optional Bimba Products
• 1 – 24 VDC Power supply [PWR-024A24-DIN] (if not supplied by user)
• 1 - IntelliSense
®
0.5 meter IO cable [CBL-IS-CF-0.5] (for EOT or power option a)
• 1 – IntelliSense
®
Junction Block [ISH-R04] (for connection to MODBUS network and power
option b)
User Supplied
• 12-24 VDC power source (if not using Bimba option)
• PLC with MODBUS RTU network compatibility
• Interface cable to connect RS-485 to PLC
• Computer for setup of IntelliSense
®
SIM
• PLC that will accepts a NPN (sinking) sensor (for use of EOT inputs)
Data Logging, Remote Monitoring, and MODBUS RTU Network / with PLC Discrete Input (appendix drawing 7 and 8)
With this setup the user may connect to the SIM unit through the Data Gateway and visually monitor the current
status of the SIM unit and attached pressure system. This setup also allows for data logging to be performed and
stored in the Data Gateway unit, regardless of a user PC connection. By conguring a Modbus RTU network be-
tween the user’s PLC (Master Device) and the SIM unit(s) (Slave Device) the user can retrieve desired status values
and alerts. If using the discrete outputs, the SIM must be powered using option b.